{"id":154,"date":"2022-11-15T08:07:57","date_gmt":"2022-11-15T08:07:57","guid":{"rendered":"https:\/\/www.qbkg.com\/?p=154"},"modified":"2024-09-04T20:15:26","modified_gmt":"2024-09-04T12:15:26","slug":"lc1-e-series-ac-contactor","status":"publish","type":"post","link":"https:\/\/www.swdlfj.com\/pt\/lc1-e-series-ac-contactor.html","title":{"rendered":"Contator CA s\u00e9rie LC1-E"},"content":{"rendered":"\r\n

O contator CA da s\u00e9rie LC1-E \u00e9 adequado para uso em circuitos com tens\u00e3o nominal de at\u00e9 660 V CA 50 Hz ou 60 Hz, corrente nominal de at\u00e9 95 A, para fazer e interromper, frequentemente iniciar e controlar o motor CA. Combinado com o bloco de contato auxiliar, atraso de tempo e contator de intertravamento de m\u00e1quina, partida estrela-tri\u00e2ngulo. Com o rel\u00e9 t\u00e9rmico, ele \u00e9 combinado na partida eletromagn\u00e9tica. O contator \u00e9 produzido de acordo com a IEC 60947-4.<\/p>\r\n

Especifica\u00e7\u00f5es<\/p>\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n
\r\n

Tipo<\/p>\r\n<\/td>\r\n

\r\n

Corrente de calor nominal (A)<\/span><\/p>\r\n<\/td>\r\n

\r\n

Corrente de trabalho nominal (A)<\/span><\/p>\r\n<\/td>\r\n

\r\n

Capacidade AC3 do motor de gaiola de esquilo trif\u00e1sico AC3 (KW)<\/p>\r\n<\/td>\r\n<\/tr>\r\n

\r\n

380V<\/span><\/p>\r\n<\/td>\r\n

\r\n

660V<\/span><\/p>\r\n<\/td>\r\n

\r\n

380V<\/span><\/p>\r\n<\/td>\r\n

\r\n

660V<\/span><\/p>\r\n<\/td>\r\n<\/tr>\r\n

\r\n

LC1E-9<\/span><\/p>\r\n<\/td>\r\n

\r\n

20<\/span><\/p>\r\n<\/td>\r\n

\r\n

9<\/span><\/p>\r\n<\/td>\r\n

\r\n

6.6<\/span><\/p>\r\n<\/td>\r\n

\r\n

4<\/span><\/p>\r\n<\/td>\r\n

\r\n

5.5<\/span><\/p>\r\n<\/td>\r\n<\/tr>\r\n

\r\n

LC1E-12<\/span><\/p>\r\n<\/td>\r\n

\r\n

20<\/span><\/p>\r\n<\/td>\r\n

\r\n

12<\/span><\/p>\r\n<\/td>\r\n

\r\n

8.9<\/span><\/p>\r\n<\/td>\r\n

\r\n

5.5<\/span><\/p>\r\n<\/td>\r\n

\r\n

7.5<\/span><\/p>\r\n<\/td>\r\n<\/tr>\r\n

\r\n

LC1E-18<\/span><\/p>\r\n<\/td>\r\n

\r\n

32<\/span><\/p>\r\n<\/td>\r\n

\r\n

18<\/span><\/p>\r\n<\/td>\r\n

\r\n

10.6<\/span><\/p>\r\n<\/td>\r\n

\r\n

7.5<\/span><\/p>\r\n<\/td>\r\n

\r\n

9<\/span><\/p>\r\n<\/td>\r\n<\/tr>\r\n

\r\n

LC1E-25<\/span><\/p>\r\n<\/td>\r\n

\r\n

40<\/span><\/p>\r\n<\/td>\r\n

\r\n

25<\/span><\/p>\r\n<\/td>\r\n

\r\n

18<\/span><\/p>\r\n<\/td>\r\n

\r\n

11<\/span><\/p>\r\n<\/td>\r\n

\r\n

15<\/span><\/p>\r\n<\/td>\r\n<\/tr>\r\n

\r\n

LC1E-32<\/span><\/p>\r\n<\/td>\r\n

\r\n

50<\/span><\/p>\r\n<\/td>\r\n

\r\n

32<\/span><\/p>\r\n<\/td>\r\n

\r\n

21<\/span><\/p>\r\n<\/td>\r\n

\r\n

15<\/span><\/p>\r\n<\/td>\r\n

\r\n

18.5<\/span><\/p>\r\n<\/td>\r\n<\/tr>\r\n

\r\n

LC1E-40<\/span><\/p>\r\n<\/td>\r\n

\r\n

60<\/span><\/p>\r\n<\/td>\r\n

\r\n

40<\/span><\/p>\r\n<\/td>\r\n

\r\n

34<\/span><\/p>\r\n<\/td>\r\n

\r\n

18.5<\/span><\/p>\r\n<\/td>\r\n

\r\n

30<\/span><\/p>\r\n<\/td>\r\n<\/tr>\r\n

\r\n

LC1E-50<\/span><\/p>\r\n<\/td>\r\n

\r\n

80<\/span><\/p>\r\n<\/td>\r\n

\r\n

50<\/span><\/p>\r\n<\/td>\r\n

\r\n

39<\/span><\/p>\r\n<\/td>\r\n

\r\n

22<\/span><\/p>\r\n<\/td>\r\n

\r\n

33<\/span><\/p>\r\n<\/td>\r\n<\/tr>\r\n

\r\n

LC1E-65<\/span><\/p>\r\n<\/td>\r\n

\r\n

80<\/span><\/p>\r\n<\/td>\r\n

\r\n

65<\/span><\/p>\r\n<\/td>\r\n

\r\n

42<\/span><\/p>\r\n<\/td>\r\n

\r\n

30<\/span><\/p>\r\n<\/td>\r\n

\r\n

37<\/span><\/p>\r\n<\/td>\r\n<\/tr>\r\n

\r\n

LC1E-80<\/span><\/p>\r\n<\/td>\r\n

\r\n

125<\/span><\/p>\r\n<\/td>\r\n

\r\n

80<\/span><\/p>\r\n<\/td>\r\n

\r\n

49<\/span><\/p>\r\n<\/td>\r\n

\r\n

37<\/span><\/p>\r\n<\/td>\r\n

\r\n

45<\/span><\/p>\r\n<\/td>\r\n<\/tr>\r\n

\r\n

LC1E-95<\/span><\/p>\r\n<\/td>\r\n

\r\n

125<\/span><\/p>\r\n<\/td>\r\n

\r\n

95<\/span><\/p>\r\n<\/td>\r\n

\r\n

49<\/span><\/p>\r\n<\/td>\r\n

\r\n

45<\/span><\/p>\r\n<\/td>\r\n

\r\n

55<\/span><\/p>\r\n<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>","protected":false},"excerpt":{"rendered":"

O contator CA da s\u00e9rie LC1-E \u00e9 adequado para uso em circuitos com tens\u00e3o nominal de at\u00e9 660 V CA 50 Hz ou 60 Hz, corrente nominal de at\u00e9 95 A, para fazer e interromper, frequentemente iniciar e controlar o motor CA. Combinado com o bloco de contato auxiliar, atraso de tempo e contator de […]<\/p>\n","protected":false},"author":1,"featured_media":155,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[9],"tags":[],"class_list":["post-154","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ac-contactor"],"_links":{"self":[{"href":"https:\/\/www.swdlfj.com\/pt\/wp-json\/wp\/v2\/posts\/154","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.swdlfj.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.swdlfj.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.swdlfj.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.swdlfj.com\/pt\/wp-json\/wp\/v2\/comments?post=154"}],"version-history":[{"count":0,"href":"https:\/\/www.swdlfj.com\/pt\/wp-json\/wp\/v2\/posts\/154\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.swdlfj.com\/pt\/wp-json\/wp\/v2\/media\/155"}],"wp:attachment":[{"href":"https:\/\/www.swdlfj.com\/pt\/wp-json\/wp\/v2\/media?parent=154"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.swdlfj.com\/pt\/wp-json\/wp\/v2\/categories?post=154"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.swdlfj.com\/pt\/wp-json\/wp\/v2\/tags?post=154"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}